INTRODUCTION
This product is a rapid charger with a high performance microprocessor and specialized operating software. Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety. Or please do use this product in company with a specialist!
- Operating voltage range: DC11.0~18.0 Volt / AC to DC adaptor (DC11.0~18.0V/5A)
- Circuit power: Max. charge power 50W / Max. discharge power5W
- Charge current range: 0.1~5.0A
- Discharge current range: 0.1~1.0A
- Current drain for balancing Li-po: 300mAh/cell
- NiCd/NiMH battery cell count: 1~15cell
- li-ion/Polymer cell count: 1~6 series
- Pb battery voltage: 2V~20V
- Weight: 277g(Net Weight)
- Dimensions: 133 x 87x 33mm
- Optimized operating software
iC6 features the so-called AUTO function that set the feeding current during the process of
charging or discharging. Especially for Lithium batteries, it can prevent the overcharging which
may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and
alarm once detecting any malfunction. All the programs of this product were controlled through
two way linkage and communication, to achieve the maximum safety and minimize the trouble.
All the settings can be configured by users!
- Internal independent lithium battery balancer
iC6 employs an individual-cell-voltage balancer. It isn't necessary to connect an external
balancer for balance charging.
- Balancing individual cells battery discharging
During the process of discharging, iC6 can monitor and balance each cell of the battery
individually. Error message will be indicated and the process will be ended automatically if the
voltage of any single one cell is abnormal.
- Adaptable to various type of lithium battery
iC6 is adaptable to various types of Lithium batteries, such as Li-ion, LiPo and the new LiFe
series of batteries.
- Fast and storage mode of lithium battery
Purposes to charge Lithium battery varies, ‘fast’ charge reduce the duration of charging,
whereas ‘store’ state can control the final voltage of your battery, so as to store for a long time
and protect useful time of the battery.
- Maximum safety
Delta-peak sensitivity: The automatic charge termination program based on the principle of the
Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process
will be terminated automatically.
- Automatic charging current limit
You can set up the upper limit of the charging current when charging your NiCd or NiMH battery;
it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.
- Capacity limit
The charging capacity is always calculated as the charging current multiplied by time. If the
charging capacity exceeds the limit, the process will be terminated automatically when you set
the maximum value.
- Temperature threshold*
The battery’s internal chemical reaction will cause the temperature of the battery to rise. If the
temperature limit is reached, the process will be terminated.
* This function is available by connecting optional temperature probe, which is not included in
our package.
- Processing time limit:
You can also limit the maximum process time to avoid any possible defect.
- Input power monitoring
To protect the car battery used as DC input power from being damaged, its voltage keeps being
monitored. If it drops below the lower limit, the process will be ended automatically.
- Data store/load
The maximum five batteries’data can be stored for users’convenience. You can keep the data
pertaining to program setting of the battery of continuous charging or discharging. Users can
call out these data at any time without any special program setting.
- Cyclic charging/discharging
1 to 5 cyclic and continuous process of charge>discharge or discharge>charge is operable for
battery refreshing and Balancing to stimulate the battery’s activity.
Safety Note
- NiCd/NiMH
Voltage level: 1.2V/cell
Allowable fast charge current: 1C-2C (depends on the performance of cell)
Discharge voltage cut off level: 0.85V/cell (NiCd), 1.0V/cell(NiMH)
- Li-ionVoltage level: 3.6V/cell
Max. charge voltage: 4.1V/cell
Allowable fast charge current: 1C or less
Min. discharge voltage cut off level: 2.5V/cell or higher
- LiPo Voltage level: 3.7V/cell
Max. charge voltage: 4.2V/cell
Allowable fast charge current: 1C or less
Discharge voltage cut off level: 3.0V/cell or higher
- LiFe Voltage level: 3.3V/cell
Max. charge voltage: 3.6V/cell
Allowable fast charge current: 4C or less
Discharge voltage cut off level: 2.0V/cell or higher
- Pb Voltage level: 2.0V/cell
(Lead-acid) Max. charge voltage: 2.46V/cell
Allowable fast charge current: 0.4C or less
Discharge voltage cut off level: 1.75V/cell or higher
|